<LOGO>
FM Transmitter Measurement Report
Created: 2024-05-20 10-18-41
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
105.50 MHz 5/5, 44 dBuV EVROPA 2
Pilot RDS Phase Difference
7.0 kHz 3.3 kHz 9 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
11 kHz 41 kHz 19019 0,0105
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-0,5 dBr -0,14 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"EVROPA 2" 2404 10 (Pop M) 1 0 1 1 10:18, 20.05.2024
RT
"- "
AF EON
92.9, 94.6, 99.3, 99.5, 99.7, 101.5, 105.1, 105.5, 106.7 MHz -
FM Scope Max at: 41 kHz MIN: 11 kHz % above 77 kHz: 0,0105 Acquired: 2024/05/20 10:18:38 Total samples: 19019 Equivalent time: 0:15:50 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,1 dBr MIN: -0,5 dBr AVE: -0,14 dBr % above 0,2 dBr: 0,0 Last value: 0,0 dBr (2024/05/20 10:18:38) 10:04 10:06 10:08 10:10 10:12 10:14 10:16 10:18 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality